R616-3-6. Exemptions.
A. These rules apply to all elevators in Utah with the following exemptions:
1. Private residence elevators installed inside a single family dwelling. Common elevators which serve multiple private residences are not exempt from these rules.
2. Elevators in buildings owned by the Federal government.
B. Owners of elevators exempted in R616-3-6.A. may request a safety inspection by Division of Boiler, Elevator and Coal Mine Safety inspectors. Code non-compliance items will be treated as recommendations by the inspector with the owner having the option as to which, if any, are corrected. Owners requesting these inspections will be invoiced at the special inspection rate. If the owner requests a State of Utah Certificate to Operate for the elevator, all of the recommendations must be completed to the satisfaction of the inspector and the owner will be invoiced the appropriate certificate fee.
R616-3-7. Inspection of Elevators, Permit to Operate, Unlawful Operations.
A. It shall be the responsibility of the Division to make inspections of all elevators when deemed necessary or appropriate.
B. Elevator inspectors shall examine conditions in regards to the safety of the employees, public, machinery, drainage, methods of lighting, and into all other matters connected with the safety of persons using or in close proximity to each elevator, and when necessary give directions providing for the better health and safety of persons in or about the same. The owner/user is required to freely permit entry, inspection, examination and inquiry, and to furnish a guide when necessary.
C. If the Division finds that an elevator complies with the applicable safety codes and rules, the owner/user shall be issued a Certificate of Inspection and Permit to Operate.
1. The Certificate of Inspection and Permit to Operate is valid for 24 months.
2. The Certificate of Inspection and Permit to Operate shall be displayed in a conspicuous location for the entire validation period. If the certificate is displayed where accessible to the general public, as opposed to being in the elevator machine room, it must be protected under a transparent cover.
D. If the Division finds an elevator is not being operated in accordance with the safety codes and rules, the owner/user shall be notified in writing of all deficiencies and shall be directed to make specific improvements or changes as are necessary to bring the elevator into compliance.
E. Pursuant to Section 34A-7-204, if the improvements or changes are not made within a reasonable time, by agreement of the division and the owner, the elevator is being operated unlawfully.
F. If the owner/user refuses to allow an inspection to be made, the elevator is being operated unlawfully.
G. If the owner/user refuses to pay the required fee, the elevator is being operated unlawfully.
H. If the owner/user operates an elevator unlawfully, the Commission may order the elevator operation to cease pursuant to Section 34A-1-104.
I. If, in the judgment of an elevator inspector, the lives or safety of employees or public are, or may be, endangered should they remain in the danger area, the elevator inspector shall direct that they be immediately withdrawn from the danger area, and the elevator removed from service until repairs have been made and the elevator has been brought into compliance.
R616-3-8. Inclined Wheelchair Lift Headroom Clearance.
A. Headroom clearance for inclined wheelchair lifts throughout the range of travel shall be not less than 80 inches (2032 mm) as measured vertically from the leading edge of the platform floor.
B. For existing facilities only, in the event that it is not technically or economically feasible to provide other means of access for disabled persons, inclined wheelchair lifts may be installed if all of the following conditions are met:
1. The appropriate building inspection jurisdiction approves the use of an inclined wheelchair lift for the specific application.
2. Headroom clearance throughout the range of travel shall be not less than 60 inches as measured vertically from the leading edge of the platform floor.
3. The passenger restriction sign as required by ASME A18.1 3.1.2.3 shall be amended as follows: "PHYSICALLY DISABLED PERSONS ONLY. NO FREIGHT. HEADROOM CLEARANCE IS LIMITED. USE ONLY IN THE SITTING POSITION".
R616-3-9. Valves in Hydraulic Elevator Operating Fluid Systems.
A. Due to the potential loss of pressure retaining capability when over torqued, bronze-bodied valves shall not be installed in the hydraulic systems of a hydraulic elevator.
B. This requirement is in effect for all new installations and remodel installations involving the hydraulic system.
C. If a bronze-bodied valve installed on an existing elevator begins to leak, that valve shall be replaced by a steel-bodied valve.
R616-3-10. Hydraulic Elevator Piping.
A. This rule establishes minimum standards for hydraulic fluid piping in hydraulic elevators. The piping specifications referred to in this rule are governed by ASME or ASTM piping specifications (e.g. ASME Specification SA-53 Table X2.4).
R616-3-11. Shunt Trips in Elevator Systems.