R655-11-7B. Outlet Materials.
All outlets will be made of appropriate materials with due regard for loading condition, seismic forces, thermal expansion, resistance to corrosion, and potential abrasion. The use of corrugated metal pipes and other thin-walled steel pipes will not be accepted unless they serve only to provide a form for a poured-in-place concrete conduit or they are specifically accepted in writing by the State Engineer.
R655-11-7C. Outlet Details.
A. All outlets shall have a trash rack to prevent clogging.
B. All outlets connected directly to a downstream pipeline shall have an emergency bypass valve.
C. All outlets shall have a suitable energy dissipater at the discharge end to prevent erosion of the downstream channel.
D. All outlets will be placed on a concrete cradle or encased in concrete unless specifically exempted by the State Engineer in writing. All conduits made of plastic materials will be fully encased. The sequencing and construction methods for secure placement of the conduit to prevent movement during pressure testing and concrete placement must be included in the design documents.
E. All outlets, with the exception of ungated outlets, shall have an operating gate or a guard gate on the upstream end.
F. All outlets shall have seepage control measures to reduce the potential for piping along the conduit. Common methods may include locating the outlet conduit in bedrock and installing a conduit filter drain to intercept seepage. Where possible, the outlet should penetrate the chimney drain so it acts as the conduit filter drain. Where an individual filter drain is used, it must have sufficient lateral extent to also protect against localized embankment cracking as well as seepage along the conduit. The use of cutoff collars is not an approved method.
G. Outlets encased or cradled in concrete should have battered sides to facilitate compaction against the concrete, unless approval is given by the State Engineer to place the conduit in a trench.
H. Every attempt should be made to locate the outlet on bedrock or consolidated materials. In the event this is not possible, consideration should be given to articulating the outlet to allow for settlement.
I. Outlet gates and valves can be either mechanically or hydraulically operated. In either case the hydraulic lines or mechanical stems must be adequately protected from debris, wave action, settlement, and ice damage. Buried stems should be encased in an oil-filled pipe supported on pedestals. No catwalks or similar access structures will be allowed on reservoirs where freezing occurs or significant floating debris is present. All outlets which are operated with motorized equipment must have back-up capability or a manual bypass system capable of being operated in a reasonable amount of time.
J. All outlets shall be properly vented. A vent pipe and air manifold around the perimeter of the conduit immediately downstream of the gate will be required unless waived by the State Engineer. The air supply lines should be conservatively sized for the anticipated flows and protected in the same manner as the outlet control lines or stems.
K. All operators and supporting equipment for outlet controls should be properly protected and secured. Particular attention needs to be given to protection from vandals and unauthorized operation. All outlet controls should be clearly marked as to which way the gates and valves operate so that overloading of a closed gate or valve should not occur.
L. Outlet controls should be accessible when the spillways are in use.
R655-11-8. Spillway Requirements.
A. On all spillway control structures, provisions should be made for aeration of the nappe.
B. All spillways excavated in soils or soft rock should include a check structure to avoid headcutting and lowering of the spillway flowline.
C. All spillway channels should have suitable armor to prevent erosion.
D. If the spillway has concrete sidewalls, adequate weepholes should be provided or the walls should be designed with full hydrostatic loads in conjunction with the soil loads.
E. For spillways in remote areas where significant snowfall occurs, efforts should be made to maximize the southern exposure of the spillway to prevent ice blockage. In many cases elimination of tall trees will be required.
F. All construction joints should be provided with adequate water stops.
G. Design provisions should be made so that downstream spillway channel flows cannot encroach on the dam.
H. All spillways draining reservoirs with large amounts of floating debris should include a log boom to avoid plugging the spillway.
I. Spillway designs should provide for energy dissipation so that waters returned to the natural channel will not cause erosion.
J. For spillways with concrete floors, provisions should be made to control uplift pressures.
K. Stop logs or flashboards which restrict the design spillway capacity will not be allowed.
R655-11-9. Other Design Requirements.
A. To facilitate inspection, all dams shall have a zone 25 feet beyond all contacts at the downstream groins and toe of the dam in which all woody vegetation is to be removed.
B. If the dam is located in an area where grazing occurs, then livestock must be restricted from the dam by suitable fencing.
C. Unless the dam crest serves as a public road, a suitable gate or other barrier should be installed to prohibit traffic.
D. Geosynthetics may not be used in a dam as the primary design feature unless specifically approved, in writing, by the State Engineer.
E. The foundation downstream of a dam should be graded to convey seepage waters and runoff away from the dam.