R307. Environmental Quality, Air Quality.R307-313. VOC and Blue Smoke Controls for Hot Mix Asphalt Plants.
R307-313-1. Purpose.
Rule R307-313 establishes emission controls and work practice standards for the emissions of blue smoke and volatile organic compounds (VOC) from hot mix asphalt plants and associated oil storage tanks.
R307-313-2. Applicability.
Rule R307-313 applies to stationary hot mix asphalt plants and their associated oil storage tanks located in Salt Lake, Davis, Weber, Utah, and Tooele counties with an annual production level greater than or equal to 250,000 tons of hot mix asphalt per rolling 12-month period. Warm mix asphalt production shall not be included in the applicable annual production level in Rule R307-313.
R307-313-3. Definitions.
Terms defined in Section R307-312-3 also apply to this rule.
"Blue smoke" means a mixture of visible emissions and VOC emissions from HMA plants that results from the process of mixing hot oil with aggregate.
"Dryer" means a piece of machinery where aggregate is dried and heated during the asphalt manufacturing process, usually drum or cylinder shaped.
"Load out" means an area used for the loading of material from a silo or a batch tower into a truck or train or other means of transport, often located under a silo.
"Silo" means a tower used to store material.
"Storage tank" means any storage vessel where oils are heated and stored before mixing with aggregate.
"Warm mix asphalt" means asphalt produced at a temperature at or below 275 degrees F (135 degrees C).
R307-313-4. Blue Smoke and VOC Emissions from Hot Mix Asphalt Plants.
(1) The owner or operator shall install emission capture and control systems that capture and reduce blue smoke emissions from dryers, conveyors, silos, and load out areas. The owner or operator shall operate emission capture and control systems at all times during the production of asphalt products. Emission capture and control systems shall also reduce VOC emissions from captured blue smoke as verified by the manufacturer of control systems.
(2) Visible emissions from emission points subject to Section R307-313-4 shall not exceed 10% opacity as measured according to 40 CFR 60, Appendix A, Method 9.
R307-313-5. VOC Emissions from Storage Tanks.
(1) Storage tanks shall be equipped with VOC capture and control systems such as a condenser and a carbon-filled vessel which shall reduce VOC emissions as verified by the manufacturer of capture and control systems.
(2) All seals and gaskets associated with tanks and capture and controls system shall be properly maintained to prevent leaks in accordance with manufacture recommendations. Properly maintained includes, no visible holes, tears, or other openings in any seal.
(3) Except during time of tank filling, emission points subject to Section R307-313-5 shall operate with no visible emissions as measured according to 40 CFR 60, Appendix A, Method 9.
R307-313-6. Recordkeeping.
(1) The owner or operator shall:
(a) Retain a copy of the manufacturer's recommendations for proper operation and maintenance of equipment in Sections R307-313-4 and R307-313-5.
(b) Establish a plan for scheduled maintenance based upon these recommendations.
(c) Maintain records showing proper operation and maintenance of equipment in accordance with the manufacturer's recommendations for equipment referenced in Sections R307-313-4 and R307-313-5.
(d) Maintain records of annual production of hot mix asphalt.
(e) Maintain records of annual production of warm mix asphalt products, and the temperature at which products were produced.
(2) These records shall be stored for at least 2 years and shall be made available to the director upon request.
R307-313-7. Compliance Schedule.
The owners and operators of hot mix asphalt plants subject to Rule R307-313 shall comply with Rule R307-313 by May 1, 2025.
KEY: air pollution, volatile organic compounds, VOC, hot mix asphalt, asphalt, aggregate, blue smoke
Date of Last Change: March 24, 2023
Authorizing, and Implemented or Interpreted Law: 19-2-104