R307. Environmental Quality, Air Quality.R307-335. Degreasing.
R307-335-1. Purpose.
The purpose of this rule is to limit volatile organic compound (VOC) emission from degreasing operations.
R307-335-2. Applicability.
R307-335 applies to degreasing operations that use VOCs and that are located in Box Elder, Cache, Davis, Salt Lake, Tooele, Utah, or Weber counties.
R307-335-3. Definitions.
The following additional definitions apply to R307-335:
"Batch open top vapor degreasing" means the batch process of cleaning and removing grease and soils from metal surfaces by condensing hot solvent vapor on the colder metal parts.
"Cold cleaning" means the batch process of cleaning and removing soils from metal surfaces by spraying, brushing, flushing or immersing while maintaining the solvent below its boiling point.
"Conveyorized degreasing" means the continuous process of cleaning and removing greases and soils from metal surfaces by using either cold or vaporized solvents.
"Freeboard ratio" means the freeboard height (distance between solvent line and top of container) divided by the width of the degreaser.
"Open top vapor degreaser" means the batch process of cleaning and removing soils from metal surfaces by condensing low solvent vapor on the colder metal parts.
R307-335-4. Cold Cleaning Facilities.
No owner or operator shall operate a degreasing or solvent cleaning operation unless conditions in R307-335-4(1) through (7) are met.
(1) A cover shall be installed which shall remain closed except during actual loading, unloading or handling of parts in cleaner. The cover shall be designed so that it can be easily operated with one hand if:
(a) The volatility of the solvent is greater than 2 kPa (15 mm Hg or 0.3 psi) measured at 38 degrees C (100 degrees F),
(b) The solvent is agitated, or
(c) The solvent is heated.
(2) An internal draining rack for cleaned parts shall be installed on which parts shall be drained until all dripping ceases. If the volatility of the solvent is greater than 4.3 kPa (32 mm Hg at 38 degrees C (100 degrees F)), the drainage facility must be internal, so that parts are enclosed under the cover while draining. The drainage facility may be external for applications where an internal type cannot fit into the cleaning system.
(3) Waste or used solvent shall be stored in covered containers.
(4) Tanks, containers and all associated equipment shall be maintained in good operating condition, and leaks shall be repaired immediately or the degreaser shall be shutdown.
(5) Written procedures for the operation and maintenance of the degreasing or solvent cleaning equipment shall be permanently posted in an accessible and conspicuous location near the equipment.
(6) If the solvent volatility is greater than 4.3 kPa (33 mm Hg or 0.6 psi) measured at 38 degrees C (100 degrees F), or if solvent is heated above 50 degrees C (120 degrees F), then one of the following control devices shall be used:
(a) Freeboard that gives a freeboard ratio greater than 0.7;
(b) Water cover if the solvent is insoluble in and heavier than water); or
(c) Other systems of equivalent control, such as a refrigerated chiller or carbon adsorption.
(7) If used, the solvent spray shall be a solid fluid stream at a pressure that does not cause excessive splashing and may not be a fine, atomized or shower type spray.
R307-335-5. Open Top Vapor Degreasers.
Owners or operators of open top vapor degreasers shall, in addition to meeting the requirements of R307-335-4(3), (4) and (5),
(1) Equip the vapor degreaser with a cover that can be opened and closed without disturbing the vapor zone. The cover shall be closed except when processing work loads through the degreaser;
(2) Install one of the following control devices:
(a) Equipment necessary to sustain:
(i) A freeboard ratio greater than or equal to 0.75, and
(ii) A powered cover if the degreaser opening is greater than 1 square meter (10.8 square feet),
(b) Refrigerated chiller,
(c) Enclosed design (cover or door opens only when the dry part is actually entering or exiting the degreaser),
(d) Carbon adsorption system, with ventilation greater than or equal to 15 cubic meters per minute per square meter (50 cubic feet per minute per square foot) of air/vapor area when cover is open and exhausting less than 25 parts per million of solvent averaged over one complete adsorption cycle;
(3) Minimize solvent carryout by: