R307. Environmental Quality, Air Quality.R307-347. Large Appliance Surface Coatings.
R307-347-1. Purpose.
The purpose of this rule is to reduce volatile organic compound (VOC) emissions from large appliance surface coating operations.
R307-347-2. Applicability.
(1) R307-347 applies to large appliance surface coating operations located in Box Elder, Cache, Davis, Salt Lake, Tooele, Utah and Weber counties.
(2) Before September 1, 2018, R307-347 applies to large appliance surface coating operations that have the potential to emit 2.7 tons per year or more of VOC, including related cleaning activities.
(3) Effective September 1, 2018, R307-347 shall apply to large appliance surface coating operations that use a combined 20 gallons or more of coating products and associated solvents per year.
R307-347-3. Exemptions.
(1) The requirements of R307-347 do not apply to the following:
(a) Stencil coatings;
(b) Safety-indicating coatings;
(c) Solid-film lubricants;
(d) Electric-insulating and thermal-conducting coatings;
(e) Touch-up and repair coatings; or
(f) Coating applications utilizing hand-held aerosol cans.
R307-347-4. Definitions.
The following additional definitions apply to R307-347:
"Air dried coating" means coatings that are dried by the use of air or a forced warm air at temperatures up to 194 degrees Fahrenheit.
"As applied" means the VOC and solids content of the finishing material that is actually used for coating the substrate. It includes the contribution of materials used for in-house dilution of the finishing material.
"Baked coating" means a coating that is cured at a temperature at or above 198 degrees Fahrenheit.
"Extreme performance coatings" means coatings designed for harsh exposure or extreme environmental conditions.
"Large appliance" means doors, cases, lids, panels, and interior support parts of residential and commercial washers, dryers, ranges, refrigerators, freezers, water heaters, dishwashers, trash compactors, air conditioners, and other similar products.
R307-347-5. VOC Content Limits.
No owner or operator shall apply coatings with a VOC content greater than the amounts specified in Table 1, unless the owner or operator uses an add-on control device as specified in R307-347-7.
TABLE 1
Large Appliance Surface Coating Limitations
(values in pounds VOC per gallon of coating, minus water and
exempt solvents(compounds not classified as VOC as defined in
R307-101-2), as applied)
Coating Category VOC Content Limits (lb/gal)
Baked Air Dried
General, one component 2.3 2.3
General, multi-component 2.3 2.8
Extreme high gloss 3.0 2.8
Extreme performance 3.0 3.5
Heat resistance 3.0 3.5
Solar absorbent 3.0 3.5
Metallic 3.5 3.5
Pretreatment coatings 3.5 3.5
R307-347-6. Work Practices.
(1) The owner or operator shall:
(a) Store all VOC-containing coatings, thinners, and cleaning materials in closed containers;
(b) Minimize spills of VOC-containing coatings, thinners, and cleaning materials;
(c) Clean up spills immediately;
(d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;
(e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and
(f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.