PAILS AND LIDSBody spray
Reconditioned interior 4.2
Reconditioned exterior 3.5
New interior 3.5
New exterior 2.8
End sealing compound 0.5
Inks, all applications 2.5
Coil
Coil coating 1.7
R307-352-5. Work Practices.
(1) The owner or operator shall:
(a) Store all VOC-containing coatings, thinners, and cleaning materials in closed containers;
(b) Minimize spills of VOC-containing coatings, thinners, and cleaning materials;
(c) Clean up spills immediately;
(d) Convey any coatings, thinners, and cleaning materials in closed containers or pipes;
(e) Close mixing vessels that contain VOC coatings and other materials except when specifically in use; and
(f) Minimize usage of solvents during cleaning of storage, mixing, and conveying equipment.
(2) No person shall apply any coating unless the coating application method has a transfer efficiency of at least 65%.
The following applications achieve a minimum of 65% transfer efficiency and shall be operated in accordance with the manufacturers specifications:
(a) Electrostatic application;
(b) Flow coat;
(c) Roll coat;
(d) Dip coat;
(e) High-volume, low-pressure (HVLP) spray;
(f) Hand application methods;
(g) Printing techniques; or
(h) Other application method capable of achieving at least 65% transfer efficiency, as certified by the manufacturer.
(3) Solvent cleaning operations shall be performed using cleaning materials having a VOC composite vapor pressure no greater than 1 mm Hg at 20 degrees Celsius, unless an add-on control device is used as specified in R307-352-6.
R307-352-6. Add-On Controls Systems Operations.
(1) If an add-on control system is used, the owner or operator shall install and maintain the add-on emission control system in accordance with the manufacturer recommendations and maintain 90% or greater capture and control efficiency. The overall capture and control efficiency shall be determined using EPA approved methods, as follows.
(a) The capture efficiency of a VOC emission control system's VOC collection device shall be determined according to EPA's "Guidelines for Determining Capture Efficiency," January 9, 1995 and 40 CFR Part 51, Appendix M, Methods 204-204F, as applicable.
(b) The control efficiency of a VOC emission control system's VOC control device shall be determined using test methods in Appendices A-1, A-6, and A-7 to 40 CFR Part 60, for measuring flow rates, total gaseous organic concentrations, or emissions of exempt compounds, as applicable.
(c) An alternative test method may be substituted for the preceding test methods after review and approval by the EPA Administrator.
R307-352-7. Recordkeeping.
(1) The owner or operator shall maintain records of the following:
(a) Records that demonstrate compliance with R307-352. Records shall include, but are not limited to, inventory and product data sheets of all coatings and solvents subject to R307-352.
(b) If an add-on control device is used, records of key system parameters necessary to ensure compliance with R307-352-6.
(i) Key system parameters shall include, but are not limited to, temperature, pressure, flow rates, and an inspection schedule.
(ii) Key inspection parameters shall be in accordance with the manufacturer's recommendations, and as required to demonstrate operations are providing continuous emission reduction from the source during all periods that the operations cause emissions from the source.
(2) All records shall be maintained for a minimum of 2 years.