There may be a small financial savings, but the amount cannot be estimated because it is so minimal. The efficiency gain from removing this step is primarily qualitative.
E. Persons other than small businesses, non-small businesses, state, or local government entities ("person" means any individual, partnership, corporation, association, governmental entity, or public or private organization of any character other than an agency):
The proposed rule may see a savings on a homeowner that would need to install a booster pump. There is no way for us to know how many homeowners would have a need to install booster pumps, so we are unable to estimate any savings.
F. Compliance costs for affected persons:
The proposed rule may see a savings on a homeowner that would need to install a booster pump.
There is no way for the Division to know how many homeowners would have a need to install booster pumps, so are unable to estimate any savings.
G. Regulatory Impact Summary Table (This table includes only fiscal impacts the agency was able to measure. If the agency could not estimate an impact, it is excluded from this table but described in boxes A through F.)
Regulatory Impact Summary Table
H. Department head comments on fiscal impact and approval of regulatory impact analysis:
The Executive Director of the Department of Environmental Quality, Tim Davis, has reviewed and approved this regulatory impact analysis.
Citation Information
7. Provide citations to the statutory authority for the rule. If there is also a federal requirement for the rule, provide a citation to that requirement:
Public Notice Information
9. The public may submit written or oral comments to the agency identified in box 1.
A. Comments will be accepted until:
10. This rule change MAY become effective on:
NOTE: The date above is the date the agency anticipates making the rule or its changes effective. It is NOT the effective date.
Agency Authorization Information
Agency head or
designee and title:
Tim Davis, Executive Director
R309. Environmental Quality, Drinking Water.
R309-540. Facility Design and Operation: Pump and Hydropneumatic Pressure Facilities.
R309-540-6. Pumps.
(1) [Capacity and Minimum Distribution System Pressure. ]A pump used to provide minimum distribution system pressure shall: (a) have the capacity to meet the maximum demand of the specific portion of the distribution system served; and
(b) be capable of providing the minimum pressure[s required by] requirements of Section R309-105-9. (2[a]) [A water supplier shall have at least two pumps installed and in operation at a booster pump facility that provides the only means available to meet the minimum distribution system pressure requirements of Section R309-105-9 for the water distribution pipeline served by the facility.]If a pump station is the only means available for a community PWS to meet the minimum distribution system pressure requirements of Section R309-105-9, the pump station shall have at least two pumps in operation.(a) Transient and non-transient non-community PWSs shall have at least one pump in operation to maintain the minimum distribution system pressure requirements of Section R309-105-9. If the director finds that unplanned closures could cause harm to public health, the director may require a transient or non-transient non-community PWSs to install at least two pumps to maintain minimum distribution pressure. (b) Transient and non-transient non-community PWSs that have only one pump in operation shall have a backup pump available that is ready to install if necessary. (3[b]) [A booster]In a pump station[facility] that requires at least two pumps, if the largest pump is out of service, the second pump shall have the capacity to meet the maximum demand of the water distribution pipeline served by the pump station.[facility with the largest pump out of service.] (4[3]) Each [B]booster [P]pump[s.]: (a) [A booster pump ]shall [be equipped with]have an automatic shutoff or low-pressure controller as recommended by the pump manufacturer;[.] (b) [A booster pump]that withdraws[ing] water from a distribution line shall maintain an intake pressure of at least 20 psi when the pump is in normal operation;[.] (c) [A booster pump]that withdraws[ing] water directly from a water storage tank shall [be provided with ]have net positive suction head. (5[4]) [Pump Motor. ]A pump motor shall: (a) [be sized]have the capacity to meet operating conditions without overloading; and (b) provide the maximum horsepower necessary to run [required by ]the pump without the use of a service factor. [(5) Certification of Drinking Water Treatment Chemicals and System Components. (a) Chemicals added to drinking water at pump facilities shall be certified to meet NSF/ANSI 60.] (6[b]) [Products, components, and]Any material[s used] that may come in contact with drinking water in a pump facility [facilities that may impart chemical contaminants or impurities to drinking water ]shall be certified to meet NSF/ANSI 61. (7[6]) [Suction Lift.]Any pump with suction lift shall:[ When a pump provides suction lift:] (a) [the maximum lift shall ]be within the pump manufacturer's recommended limits; and (b) [tanks]have priming [shall be provided ]for the pump. ](8[a]) When a pump requires priming, the priming system shall: (a[i]) use water of at least the same quality that the pump is pumping; [as the water being pumped; ]and (b[ii]) include a means to prevent back siphoning. (9[b]) For vacuum priming that uses an [When an ]air-operated ejector, the ejector [is used for vacuum priming, it ]shall draw clean air through a screened intake that is: (a[i]) at least ten feet above the ground; and (b[ii]) at least ten feet away from a point of contamination. ](10[a]) A pump that uses water for a seal [Water used as a seal for a pump ]shall have water [be ]of at least the same quality that the pump is pumping[of the water being pumped].[ (b) ] A water line supplying drinking water [used as ]for a seal for a pump that pumps non-potable water shall have backflow protection.[be protected from backflow.] [(9) Individual Home Booster Pumps. Individual home booster pumps shall not be allowed for any individual service from the public water supply main. Exceptions may be granted by the Director if it can be shown that the granting of an exception will not jeopardize public health. ](11) A booster pump within the premise plumbing of a building or on the service lateral connection, including a home booster pump, is acceptable if: (a) the pump is not necessary to resolve deficiencies related to the necessary minimum pressures at the point of connection for the service lateral per Section R309-105-9; (b) the PWS approves the pump installation; and (c) the pump installation and operation meet the applicable requirements in the International Plumbing Code and any amendments that the Department of Commerce has adopted. R309-540-8. Hydropneumatic Facilities[ for Maintaining Distribution System Pressure]. (a) Section R309-540-8 applies to a hydropneumatic facility that maintains distribution system pressure for a public water system. (b) Sections R309-540-5 through R309-540-7 apply to a pump, other than a well pump, that supplies water under pressure to a hydropneumatic pressure tank.] (1[c]) Section R309-540-8 applies to air-over-water, diaphragm, and bladder hydropneumatic pressure tanks. (2[d]) Section R309-540-8 does not apply to: (a[i]) a surge protection tank; (b[ii]) pressure relief equipment; or (c[iii]) a pressure tank dedicated solely to fire suppression. (3[2]) [Number of Pumps. A public water system using a hydropneumatic facility to meet the minimum distribution system pressure requirements of Section R309-105-9 shall have at least two pumps installed and in operation at the hydropneumatic facility, unless the hydropneumatic facility is supplied solely by a well pump.]Where a hydropneumatic facility is the only means available for a PWS to meet the minimum distribution system pressure requirements of Section R309-105-9, the number of pumps shall meet the requirements in Subsection R309-540-6(2). (4[3]) [Pressure Tank Certification. ]A hydropneumatic pressure tank shall have: (a) NSF/ANSI 61 certification; and
(b) ASME Boiler and Pressure Vessel Code certification.
(5[4]) [Use of Pressure Tank Volume for Water Storage Sizing. ]A community water system may not use the volume of a hydropneumatic pressure tank to meet the water storage sizing requirements in Section R309-510-8.[(5) Pressure Tank Located Below Ground.] (6[a]) A below-ground location for a hydropneumatic pressure tank and appurtenances shall meet the requirements of: (a[i]) Subsection R309-540-5(2) for flood protection and site drainage; (b[ii]) Subsection R309-540-5(4[3]) for pump station drainage and flooding prohibition; (c[iii]) Subsection R309-540-5(5[4])[(b)] for access; and (d[iv]) Subsection R309-540-5(9[8]) for ventilation. (7[b]) Electrical controls for a hydropneumatic pressure tank located below ground shall be: (a[i]) located above grade; and (b[ii]) protected from flooding. (8[6]) [Operating Pressure Measurement. A ]Hydropneumatic facilities shall have means to measure the operating pressures[ of a hydropneumatic facility shall be provided]. (9[7]) [Bypass Piping. ]Each hydropneumatic tank shall have bypass piping and isolation valves to allow draining and maintenance of the tank [to be removed from service ]without disruption of water distribution. (10[8]) [Pressure Tank Sizing. ]The [minimum ]volume of a hydropneumatic tank shall be large enough [sized ]to avoid continuous pump cycling as recommended by the manufacturer. [(9) Air-Over-Water Pressure Tanks.] (11[a]) An air-over-water pressure tank shall have: (a[i]) an access opening; (c[iii]) a means to measure pressure; (d[iv]) a means to measure the water level in the tank; (e[v]) an automatic or manual air blow-off; (f[vi]) a means for adding air; and (g[vii]) pressure operated start-stop controls for a pump. (12[b]) Air delivered by a compressor to an air-over-water pressure tank shall be: (a[i]) drawn from a point above ground; (b[ii]) free of contamination; (13[c]) The volume of water remaining in an air-over-water pressure tank at the lowest pressure setting shall provide a water seal at the water outlet to prevent the leakage of air. KEY: drinking water, pumps, hydropneumatic systems, individual home booster pumps
Date of Last Change: 2026[June 26, 2024] Notice of Continuation: February 10, 2025
Authorizing, and Implemented or Interpreted Law: 19-4-104